The UK's Leading Thermographic Inspection, Rental & Sales Supplier
ThermaCAM™ P65
High performance portable infrared camera system: The Professional Thermographer’s Choice.
The ThermaCAM™ P65 takes high-definition 14-bit thermal images. At the same time, it records visual images with its built-in digital camera FLIR Systems has recognized the importance of having a visual image as a reference against the thermal image Engineers who detect problems with the infrared camera are often not the same people as those who have to repair the defects. The ability to view the environment in which a problem is located on a visual image makes the job a lot easier. With the ThermaCAM™ P65, all this is done automatically. There is no need to carry separately a digital camera.
The integrated Laser LocatIR™, activated at the touch of a button, helps you to safely and quickly associate a hot spot shown on the IR image with the problem area on the physical target.
Sample Shots
-
ThermaCAM™ P60
320x240 resolution -
ThermaCAM™ E45
160x120 resolution -
InfraCAM™ SD
120x120 resolution
Technical Specification
IMAGING PERFORMANCE |
|
| Field of view/min focus distance | 24° X 18°/0.3m |
| Spatial resolution (IFOV) | 1.3 mrad |
| Thermal sensitivity | 0.08 °C |
| Frame rate | 50Hz/60 Hz |
| Focus | Automatic or manual |
DETECTOR |
|
| Type | Uncooled microbolometer |
| Array format | 320 x 240 |
| Spectral response | 7.5 -13 microns |
| Visual digital camera | 640 X 480 pixels, full color |
IMAGE PRESENTATION |
|
| Viewfinder | High-resolution colour LCD (TFT) |
| External display | Detachable 4" LCD with integrated remote control |
| Video output | NTSC/PAL, IEEE-1394 DV |
| Auto/manual adjust | Continuous auto adjust for level, level & span Auto adjust with scale lock for level max, level min or span Manual adjust for level and span |
MEASUREMENT |
|
| Accuracy | +/- 2 °C, +/- 2% of reading |
| Temperature range | -40 °C to +120 °C and 0 °C to +500 °C Up to +1500 °C / +2000 °C (optional) |
| Measurement mode | Spot/manual (up to 10 movable), Spot/automatic placement and reading max and min within area Area (up to 5 circles and 5 boxes, movable ) Isotherms, Profile and Delta T |
| Emissivity correction | Variable from 0.1 to 1.0 or selected from predefined material list |
| Measurement corrections | Reflected ambient, distance, relative humidity, external optics |
IMAGE STORAGE |
|
| Type | Built-in flash memory (50 images) Removable compact flash PC card (256MB) Built-in RAM for burst and AVI recording |
| File format - Thermal | JPEG with 14 bit measurement data Burst and AVI |
| File format - Visual | JPEG with movable marker, linked with corresponding thermal image |
| Voice annotation | Up to 30 sec digital voice stored with each image, Bluetooth wireless earpiece |
| Text annotation | Predefined text selected or beamed from PDA, stored with the image |