A mechanical thermography survey images motors, pumps, bearing housings, couplings, belt and pulley drives and generators while they run, to find parts reading warmer than matching plant in the same conditions. Ti Thermal Imaging’s ITC-trained thermographers survey mechanical and electrical plant in one visit and deliver the report the same day, with each finding located, imaged and measured.

What gets surveyed
- Motors: casings, terminal boxes and the supply cables feeding them.
- Bearings: the bearing housings at each end of motors, pumps, fans and shafts.
- Couplings, belts and pulleys: drive ends where alignment or belt tension problems tend to show as extra heat.
- Pumps and fans: pump bodies, seals and drive ends on water, HVAC and process duty.
- Generators: output connections, control panels and changeover supplies while the set is running on load or on its test run.
Because the same thermographer can cover the electrical side on the same day (switchboards, distribution boards, MCCs and drives), most sites book the two together and get one dated record of the plant.
What thermography shows, and what it doesn’t
A thermal camera measures surface temperature. On mechanical plant it shows where a bearing housing, coupling or motor is reading warmer than the matching item next to it, or warmer than the same item read at last year’s survey under the same conditions. It does not tell you why. Friction, lubrication, alignment and loading can all add heat, and the report does not guess between them. It records what was measured and where, and recommends the next step, such as vibration analysis or a mechanical inspection by your fitters.
Some surfaces need care. Bare and polished metal on shafts and couplings reflects heat from its surroundings, so readings are taken on painted or matt surfaces where possible, and machines are compared like with like. Process heat from hot pipework or nearby plant is ruled out before anything is reported.
Why the plant must be running
A worn bearing or a slipping belt only gives off extra heat while the machine is turning, in the same way a weak electrical joint only shows while current flows. On a London data centre build, commissioning thermography by our team found 16 busbar sections reading above 80 °C under test load, the highest 103.5 °C at a tap-off unit. None of that is visible on a quiet day. Mechanical surveys are booked when the plant is at its normal duty for the same reason, and the running state is recorded against each finding.
What you get in the report
- Every machine surveyed listed, not just the ones with findings, plus anything that could not be seen (for example behind a fixed guard) and why.
- For each finding: location, a thermal and visual image pair, the measured temperature and where it was taken, and the difference in °C from the matching reference.
- The running state at the time, so next year’s survey compares like with like.
- A priority and a recommended next step.
- Same-day delivery from our own reporting software, TICOR, with the results held online in WEBCOR so you can share them and trend each machine year on year.
Independent, inspection only
Ti inspects and reports. We do not repair or service plant, so nothing in the report is there to win follow-on work. Ti is an independent thermography company led by ITC Level 3 certified thermographers, trading since 2002. More on independent thermal imaging reports for UK facilities.
Frequently asked questions
Can thermography find a bearing fault?
It finds bearing housings running warmer than comparable ones in the same conditions. It does not diagnose the cause; that is a job for vibration analysis or a mechanical inspection.
Do machines have to stop for the survey?
No. The survey only works with plant running at its normal duty. Everything is imaged from a safe distance with guards in place.
Can mechanical and electrical plant be surveyed in the same visit?
Yes. Most sites book both together so motors, pumps and drives are covered alongside the boards and switchgear that feed them, in one report.
Related reading
- Data centre electrical thermography
- Busbar thermography at commissioning
- Switchgear thermography
- Annual PPM electrical thermography
- 7 electrical risks thermography finds
Our work has featured on BBC News and ITV.
Talk to us: +44 20 3885 7464 · sales@thermalimaging.co.uk · contact page
About the author: Rachael Browning, General Manager, Ti Thermal Imaging.