Data Centre Thermography in Germany: Frankfurt and Hesse

Ti Thermal Imaging surveys data centres in Frankfurt, the surrounding Hesse towns and across Germany. Our ITC Level 3 thermographers image switchgear, busbar, UPS, PDUs, ATS and generator connections under load with nothing switched off, and report the same day.

We inspect and report. Your electrical contractor carries out repairs. See our European data centre thermography overview.

Plan a German data centre survey or call +44 20 3885 7464.

Why it matters in Germany

Frankfurt is Europe’s main interconnection hub, and it is one of the tightest markets for power. New development is moving out of the city into surrounding Hesse towns, while the existing Frankfurt halls stay full.

Germany also regulates data centres directly. The Energy Efficiency Act (EnEfG) puts data-centre-specific duties on operators, including annual reporting of energy data, and stricter efficiency requirements for newer sites. A draft amendment is changing some of the detail, so operators should check the current text with their advisers.

Thermography is not an EnEfG requirement. What it gives an operator is a dated, imaged record of the condition of the electrical installation, which fits a site that is already measuring and documenting more than it used to. A hot connection also wastes energy as heat before it fails.

What we survey on German sites

  • HV and LV switchgear and main distribution boards
  • Busbar trunking, risers and tap-off units
  • UPS, static switches and battery connections
  • PDUs and remote power panels
  • Generator connections and ATS
  • Cooling plant: CRAH units, chillers, pumps and motors

How we work from the UK

We plan travel, equipment and site access with you before the survey date, and work inside your site rules, induction and permit to work. Your electrician opens panels, and our thermographer never touches live equipment. Reports are in English and include a thermal image and photo for every finding, the measured temperature, the load at the time, a severity grade and a recommended action. Recurring surveys on one asset register show trend: see annual PPM thermography. For new builds, see commissioning thermography in Europe.

Frequently asked questions

Who does data centre thermography in Frankfurt and Germany?

Ti Thermal Imaging, a Level 3 certified thermography company based in the UK. Our ITC Level 3 thermographers travel to Frankfurt, the surrounding Hesse towns and other German sites.

Is thermography required under the EnEfG?

No. The Energy Efficiency Act (EnEfG) sets energy reporting and efficiency duties for data centre operators. Thermography is a maintenance and condition record, not a reporting duty under that Act.

How does thermography help an operator who is documenting more under the EnEfG?

It gives a dated, imaged record of the condition of the electrical installation, with measured temperatures and the load at the time. A hot connection also wastes energy as heat before it fails.

Do you survey new data centres in Hesse as well as Frankfurt?

Yes. New development is moving into the surrounding Hesse towns, and we will travel to any German site, including at commissioning during load bank testing.

Do you need a shutdown?

No. Nothing is switched off. Your electrician opens panels under your permit to work, and our thermographer never touches live equipment.

How often should a German data centre be surveyed?

Most operators survey critical power equipment every six months, and at least annually. Recurring surveys on one asset register show which findings were fixed and which assets are getting worse.

What language is the report in?

English.